// SPDX-License-Identifier: BSD-3-Clause
//
package redfish
import (
"encoding/json"
"strings"
"testing"
)
var coolingUnitBody = `{
"@odata.type": "#CoolingUnit.v1_1_1.CoolingUnit",
"Id": "1",
"EquipmentType": "CDU",
"Name": "Rack #4 Cooling Distribution Unit",
"FirmwareVersion": "3.2.0",
"Version": "1.03b",
"ProductionDate": "2020-12-24T08:00:00Z",
"Manufacturer": "Contoso",
"Model": "BRRR4000",
"SerialNumber": "29347ZT536",
"PartNumber": "ICE-9",
"AssetTag": "PDX5-92381",
"Status": {
"State": "Enabled",
"Health": "OK"
},
"Location": {
"Placement": {
"Row": "North 1"
}
},
"PrimaryCoolantConnectors": {
"@odata.id": "/redfish/v1/ThermalEquipment/CDUs/1/PrimaryCoolantConnectors"
},
"SecondaryCoolantConnectors": {
"@odata.id": "/redfish/v1/ThermalEquipment/CDUs/1/SecondaryCoolantConnectors"
},
"Pumps": {
"@odata.id": "/redfish/v1/ThermalEquipment/CDUs/1/Pumps"
},
"Filters": {
"@odata.id": "/redfish/v1/ThermalEquipment/CDUs/1/Filters"
},
"EnvironmentMetrics": {
"@odata.id": "/redfish/v1/ThermalEquipment/CDUs/1/EnvironmentMetrics"
},
"LeakDetection": {
"@odata.id": "/redfish/v1/ThermalEquipment/CDUs/1/LeakDetection"
},
"Links": {
"Facility": {
"@odata.id": "/redfish/v1/Facilities/Room237"
}
},
"@odata.id": "/redfish/v1/ThermalEquipment/CDUs/1"
}`
// TestCoolingUnit tests the parsing of CoolingUnit objects.
func TestCoolingUnit(t *testing.T) {
var result CoolingUnit
err := json.NewDecoder(strings.NewReader(coolingUnitBody)).Decode(&result)
if err != nil {
t.Errorf("Error decoding JSON: %s", err)
}
assertEquals(t, "1", result.ID)
assertEquals(t, "Rack #4 Cooling Distribution Unit", result.Name)
assertEquals(t, "CDU", string(result.EquipmentType))
assertEquals(t, "3.2.0", result.FirmwareVersion)
assertEquals(t, "1.03b", result.Version)
assertEquals(t, "29347ZT536", result.SerialNumber)
assertEquals(t, "North 1", result.Location.Placement.Row)
assertEquals(t, "/redfish/v1/ThermalEquipment/CDUs/1/PrimaryCoolantConnectors", result.primaryCoolantConnectors)
assertEquals(t, "/redfish/v1/ThermalEquipment/CDUs/1/SecondaryCoolantConnectors", result.secondaryCoolantConnectors)
assertEquals(t, "/redfish/v1/ThermalEquipment/CDUs/1/Pumps", result.pumps)
assertEquals(t, "/redfish/v1/ThermalEquipment/CDUs/1/Filters", result.filters)
assertEquals(t, "/redfish/v1/ThermalEquipment/CDUs/1/EnvironmentMetrics", result.environmentMetrics)
assertEquals(t, "/redfish/v1/ThermalEquipment/CDUs/1/LeakDetection", result.leakDetection)
assertEquals(t, "/redfish/v1/Facilities/Room237", result.facility)
}