Notifications
You must be signed in to change notification settings - Fork 1
/
Copy pathquestion.json
2802 lines (2802 loc) · 114 KB
/
question.json
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
[
{
"id": 0,
"question": "电流通过人体能引起肌肉不自觉收缩的最小电流值称为()。",
"A": "摆脱阈",
"B": "反应阔",
"C": "感知阔",
"D": "心脏电流系数",
"type": "单选"
},
{
"id": 1,
"question": "变压器室位于容易沉积可燃粉尘、可燃纤维的场所时,可燃油油浸变压器室应设置容量为()变压器油量的挡油设施,或设置容量为()变压器油量挡油池并能将油排到安全处所的设施。",
"A": "80%,20%",
"B": "100%,50%",
"C": "100%,20%",
"D": "90%, 40%",
"type": "单选"
},
{
"id": 2,
"question": "当IT,系统不引出N线,线路标称电压为220/380V,配电线路发生第二次异相接地故障时保护电器应在()内切断故障回路,并符合式()的要求。式中Z表示包括相线和PE线在内的故障回路阻抗单位为Ω;I表示保护电器切断故障回路的动作电流单位为A;U表示相线对地标称电压单位为V。",
"A": "0.4s, Z*I≤50V",
"B": "0. 4s, Z*I≤√3/2 U",
"C": "0.8s, Z,I≤2U",
"D": "0.8s, Z,I≤1/2 U",
"type": "单选"
},
{
"id": 3,
"question": "在爆炸性气体危险区域为1区的场所内,电缆线路()有中间接头。",
"A": "一般不得",
"B": "严禁",
"C": "不宜",
"D": "可以",
"type": "单选"
},
{
"id": 4,
"question": "在火灾危险环境 23 区内固定安装的正常运行时有滑环等火花部件的电机,选用()防护结构最适合。",
"A": "IP44",
"B": "IP21",
"C": "IP54",
"D": "IP2X",
"type": "单选"
},
{
"id": 5,
"question": "两台 35kV 油浸变压器之间的最小防火净距为()。",
"A": "3m",
"B": "5m",
"C": "6m",
"D": "8m",
"type": "单选"
},
{
"id": 6,
"question": "总等电位连接主母线的截面应大于装置最大保护线截面的一半,并不应小于铜导线()。",
"A": "16mm²",
"B": "10mm²",
"C": "6mm²",
"D": "4mm²",
"type": "单选"
},
{
"id": 7,
"question": "在游泳池的水池内只允许用标称电压不超过()的安全超低压供电。",
"A": "6V",
"B": "12V",
"C": "24V",
"D": "36V",
"type": "单选"
},
{
"id": 8,
"question": "安全超低电压(SELV)和功能超低电压(PELV)的标称电压为()。",
"A": "≤24V",
"B": "≤36V",
"C": "≤50V",
"D": "≤100V",
"type": "单选"
},
{
"id": 9,
"question": "某变电所有一台额定容量为 8000kVA 的电力变压器,其空载损耗为 10.9kW,短路损耗为52.8kW,变压器负载系数为0.457,当变压器二次侧负载功率因数$cos\\phi_2$=0.9时,该变压器的效率为()。",
"A": "0.905",
"B": "0.972",
"C": "0.993",
"D": "0.999",
"type": "单选"
},
{
"id": 10,
"question": "异步电动机空载时,功率因数很低。负载逐渐增加时,功率因数上升。当异步电动机()额定负载时,功率因数达到最大值。",
"A": "接近",
"B": "达到",
"C": "超过5%",
"D": "超过7%",
"type": "单选"
},
{
"id": 11,
"question": "企业在提高自然功率因数的基础上,应在负荷侧合理装置集中与就地无功补偿设备,在企业最大负荷时的功率因数应不低于()。",
"A": "0.88",
"B": "0.9",
"C": "0.92",
"D": "0.95",
"type": "单选"
},
{
"id": 12,
"question": "某供电部门将配电线路导线由 LGJ-25 更换为 LGJ-35。在输送负荷不变的条件下,忽略更换前后线路电抗值的变化,简化计算换线后降低功率损耗()(LGJ-25导线电阻R=1.38Ω/km,LGJ-35 导线电阻 $R_2$=0.85Ω/km)。",
"A": "0.608",
"B": "50. 6%",
"C": "0.453",
"D": "0.384",
"type": "单选"
},
{
"id": 13,
"question": "10kV电网奇次谐波电压含有率限值为(),电压总谐波畸变率限值为()。",
"A": "4.0%, 5.0%",
"B": "1.2%, 3.0%",
"C": "3.2%, 4.0%",
"D": "2.4%, 3.0%",
"type": "单选"
},
{
"id": 14,
"question": "某面积为200m²主计算机房内无线电干扰场强,在频率为0.15~1000MHz时不应大于()。",
"A": "126dB",
"B": "105dB",
"C": "85dB",
"D": "68dB",
"type": "单选"
},
{
"id": 15,
"question": "如采用需要系数法,在换算短时或周期工作制的电动机的设备功率时,统一负载持续率应取()。",
"A": "0.15",
"B": "0.25",
"C": "0.4",
"D": "1",
"type": "单选"
},
{
"id": 16,
"question": "负荷计算时,整流器的设备功率应为()。",
"A": "额定交流视在功率",
"B": "额定交流有功功率",
"C": "额定直流输出功率",
"D": "直流用电设备的计算功率",
"type": "单选"
},
{
"id": 17,
"question": "单相负荷换算为等效三相负荷时,如只有一个线间负荷,等效三相负荷应取线间负荷的()倍。",
"A": "√3",
"B": "3",
"C": "3+√3",
"D": "3-√3",
"type": "单选"
},
{
"id": 18,
"question": "中断供电将造成大量人员集中的重要公共场所秩序严重混乱时,应为()。",
"A": "一级负荷",
"B": "二级负荷",
"C": "三级负荷",
"D": "一级负荷中特别重要负荷",
"type": "单选"
},
{
"id": 19,
"question": "甲级体育场的比赛场照明,应为()。",
"A": "一级负荷",
"B": "二级负荷",
"C": "三级负荷",
"D": "一级负荷中特别重要负荷",
"type": "单选"
},
{
"id": 20,
"question": "I类修车库用电应为()。",
"A": "一级负荷",
"B": "二级负荷",
"C": "三级负荷",
"D": "一级负荷中特别重要负荷",
"type": "单选"
},
{
"id": 21,
"question": "建筑高度超过 50m 的乙、丙类厂房和丙类仓库,其消防用电设备应为()。",
"A": "一级负荷",
"B": "二级负荷",
"C": "三级负荷",
"D": "一级负荷中特别重要负荷",
"type": "单选"
},
{
"id": 22,
"question": "对一级负荷供电电源的要求是()。",
"A": "必须两回 6kV 及以上的线路供电",
"B": "应由两回 6kV及以上的专用线路供电",
"C": "应由两个电源供电,当一个电源发生故障时,另一个电源应不致同时受到损坏",
"D": "除由两个电源供电外,尚应增设应急电源",
"type": "单选"
},
{
"id": 23,
"question": "当一级负荷中特别重要负荷允许中断供电的时间为毫秒级时,可采用的应急电源是()。",
"A": "快速自启动的发电机组",
"B": "带自动投入装置的、独立于正常电源的专用馈电线",
"C": "手动切换的独立于正常电源的专用馈电线路",
"D": "蓄电池静止型不间断供电装置、蓄电机械贮能电机型供电装置或柴油机不间断供电装置",
"type": "单选"
},
{
"id": 24,
"question": "在TN及 TT 系统接地型式的低压电网中,三相配电变压器的接线组别宜选用()。",
"A": "YynO",
"B": "Dynll",
"C": "Ydll",
"D": "YNdll",
"type": "单选"
},
{
"id": 25,
"question": "中性点经消弧线圈接地的最好运行方式是()。",
"A": "全补偿",
"B": "欠补偿",
"C": "过补偿,手动控制过补偿量为适当值",
"D": "过补偿,自动控制过补偿量为适当值",
"type": "单选"
},
{
"id": 26,
"question": "对远离变电所的小面积一般工作场所的照明、应急照明、道路照明和警卫照明,在正常情况下,用电设备端子处的电压偏差(以额定电压百分数表示)可为()。",
"A": "±10%",
"B": "±7%",
"C": "+5,-10%",
"D": "+10,-5%",
"type": "单选"
},
{
"id": 27,
"question": "当配电变压器变压比为10(6)±5%/0.4kV时,如将分接头放在+5%,低压侧电压提升率以标称电压0.38kV表示,应约为()。",
"A": "-0.05",
"B": "±0%",
"C": "0.05",
"D": "0.1",
"type": "单选"
},
{
"id": 28,
"question": "高压钠灯的光通量,当电压降10%时,光通量降低()。",
"A": "0.19",
"B": "0.37",
"C": "0.45",
"D": "0.55",
"type": "单选"
},
{
"id": 29,
"question": "高压电容器组与放电装置之间()。",
"A": "不应设置开关或熔断器,而应直接连接(不含保护单台电容器的熔断器)",
"B": "可以设置自动接通的触点",
"C": "可以设置断路器",
"D": "可以设置负荷开关",
"type": "单选"
},
{
"id": 30,
"question": "配电所的10kV或6kV非专用电源线的进线侧,应装设()。",
"A": "带保护的开关设备",
"B": "不带保护的开关设备",
"C": "隔离插头",
"D": "隔离开关",
"type": "单选"
},
{
"id": 31,
"question": "当出线为架空线时,10(6)kV固定式配电装置出线断路器的线路侧()。",
"A": "应装设隔离开关",
"B": "可不装设隔离开关",
"C": "严禁装设隔离开关",
"D": "不应装设隔离开关",
"type": "单选"
},
{
"id": 32,
"question": "当出线回路较多、或有并列运行要求、或有继电保护和自动装置要求时,降压变电所主变压器二次侧(10kV或6kV)的总开关,应采用()。",
"A": "隔离开关",
"B": "隔离触头",
"C": "熔断器",
"D": "断路器",
"type": "单选"
},
{
"id": 33,
"question": "当10kV及以下变电所高压断路器的电磁操动机构采用硅整流合闸时,宜设两回路·所用电源,并注意其中一路应引自()。",
"A": "母线电压互感器",
"B": "连接在另一段母线上的所用变压器",
"C": "接在电源进线断路器前面的所用变压器",
"D": "另一段母线电压互感器",
"type": "单选"
},
{
"id": 34,
"question": "35~110kV变电所采用内桥接线时,为了在检修进线断路时保证不中断线路供电,常在进线断路器的外侧增设带两组隔离开关的跨条,请问在跨条上设置两组串联的隔离开关的目的是()。",
"A": "互为备用",
"B": "可选用较低额定电压的隔离开关",
"C": "可选用较低额定电流的隔离开关",
"D": "检修隔离开关时,不至于要求两回进线全部停电",
"type": "单选"
},
{
"id": 35,
"question": "负荷的非线性,主要影响电能质量指标中的()。",
"A": "电压不平衡度",
"B": "电压偏移",
"C": "电压波动和闪变",
"D": "波形畸变",
"type": "单选"
},
{
"id": 36,
"question": "电力系统正常频率偏差的允许值为()。",
"A": "±0.1Hz",
"B": "±0.2Hz",
"C": "±0.3Hz",
"D": "±0.4Hz",
"type": "单选"
},
{
"id": 37,
"question": "谐波含有率(HR)是指()。",
"A": "对周期性交流量进行傅里叶分解,得到频率为基波频率的整流倍(大于1)的分量",
"B": "从周期性交流量中减去基波分量所得的量",
"C": "谐波频率与基波频率的整数比",
"D": "周期性交流量中含有的第h次谐波分量的方均根值与基波分量的方均根值之比(用百分数表示)",
"type": "单选"
},
{
"id": 38,
"question": "在配电线路受端加装并联电容器以减少线路电压损失,其适用的情况是()。",
"A": "受端负荷的自然功率因数很高",
"B": "配电线路的感性电抗很小",
"C": "配电线路的感性电抗虽然很大,但受端负荷的自然功率因数已接近于1.0",
"D": "受端负荷的自然功率因数低,而配电线路的感性电抗又很大",
"type": "单选"
},
{
"id": 39,
"question": "10kV及以下高压配电装置室,当电源从柜(屏)后进线且需在柜(屏)正背后墙上另设隔离开关及其手动操动机构时,柜(屏)后通道净宽不应小于()。",
"A": "2.0m",
"B": "1.8m",
"C": "1.5m",
"D": "1.3m",
"type": "单选"
},
{
"id": 40,
"question": "民用主体建筑内的附设变电所和车间内变电所的可燃油浸变压器室,应设置容量为()变压器油量的贮油池。5110kV及以下变配电所所址选择及电气设备布置。",
"A": "0.5",
"B": "1",
"C": "0.8",
"D": "0.2",
"type": "单选"
},
{
"id": 41,
"question": "在同一配电室内单列布置高、低压配电装置时,当高压开关柜或低压配电屏顶面有裸露带电导体时,两者之间的净距不应小于()。当高压开关柜和低压配电屏的顶面封闭外壳防护等级符合IP2X级时可靠近布置。",
"A": "0.8m",
"B": "2.0m",
"C": "1.5m",
"D": "1.0m",
"type": "单选"
},
{
"id": 42,
"question": "成套电容器柜单列布置时,柜正面与墙面的距离不应小于1.5m;当双列布置时,柜面之间最小距离应不小于()。",
"A": "1.5m",
"B": "1.6m",
"C": "2.0m",
"D": "1.9mo",
"type": "单选"
},
{
"id": 43,
"question": "3~63kV屋内或屋外配电装置中,同一电压等级的不同相带电部分之间的安全净距()带电部分至接地部分之间的安全净距。",
"A": "不等于",
"B": "等于",
"C": "大于",
"D": "小于",
"type": "单选"
},
{
"id": 44,
"question": "当屋外油浸变压器之间的距离不满足防火净距要求时应设置防火墙。考虑散热问题,防火墙离变压器外廓距离以不小于()为宜。",
"A": "0.5m",
"B": "1. 0m",
"C": "1.5m",
"D": "2.0m",
"type": "单选"
},
{
"id": 45,
"question": "低压配电室内的固定式配电屏单排布置或双排面对面布置、屏后通道仅作维护用时,其屏后通道的最小宽度应不小于()。",
"A": "700mm",
"B": "1000mm",
"C": "900mm",
"D": "800mm",
"type": "单选"
},
{
"id": 46,
"question": "低压配电室内的抽屉式配电屏,当单排布置或双排面对面布置或双排背对背布置时,其屏后通道最小宽度应不小于()。",
"A": "700mm",
"B": "800mm",
"C": "900mm",
"D": "1000mm",
"type": "单选"
},
{
"id": 47,
"question": "埋地敷设在严寒地区的电缆应埋设于冻土层以下,当无法深埋时,可在土壤排水性好的干燥冻土层或回填土中埋设,也可采取防止电缆受损伤的其他措施或在电缆的上方和下方增加细砂层的厚度,上下方各增加的厚度不宜小于()。",
"A": "100mm",
"B": "150mm",
"C": "180mm",
"D": "200mm",
"type": "单选"
},
{
"id": 48,
"question": "3~110kV屋外配电装置中,当电气设备外绝缘体最低部位距地面小于()时应装设固定遮栏。",
"A": "2.8m",
"B": "2.5m",
"C": "3m",
"D": "4m",
"type": "单选"
},
{
"id": 49,
"question": "当变电所需要设置实体围墙时,其围墙高度宜不低于(),因为该高度已能阻止人翻越围墙。",
"A": "1.5m",
"B": "1.8m",
"C": "2.2m",
"D": "2.1m",
"type": "单选"
},
{
"id": 50,
"question": "在装有避雷针、避雷线的构架上()架设低压线、通信线和广播线(符合安装要求和照明灯电源线除外)。",
"A": "可以",
"B": "不宜",
"C": "允许",
"D": "严禁",
"type": "单选"
},
{
"id": 51,
"question": "直埋敷设的电缆与铁路、公路或街道交叉时,应穿于保护管,且保护范围超出路基、街道路面两边以及排水沟边()以上。",
"A": "0.1m",
"B": "0.2m",
"C": "0.5m",
"D": "0.4m",
"type": "单选"
},
{
"id": 52,
"question": "在校验电器和载流导体的稳定性时,一般以()运行方式下的三相短路电流为依据。",
"A": "正常",
"B": "最小",
"C": "最大",
"D": "满足负荷",
"type": "单选"
},
{
"id": 53,
"question": "高压电器和导体的动稳定,一般按()校验。",
"A": "两相短路",
"B": "三相短路",
"C": "单相接地短路",
"D": "两相接地",
"type": "单选"
},
{
"id": 54,
"question": "已知变压器额定容量为4MVA,阻抗电压百分值$u_k$%=5.5,电压为10.5/6.3kV,则在基准容量为 $S_j$=100MVA下的电抗标幺值为()。",
"A": "1.5",
"B": "1.75",
"C": "1.375",
"D": "2",
"type": "单选"
},
{
"id": 55,
"question": "已知限流电抗器额定电压为6kV,额定电流为0.3kV,电抗百分值为4%,则在基准容量为$S_j$=100MVA下的电抗标幺值为()。",
"A": "1.539",
"B": "0.04",
"C": "1.164",
"D": "0.08",
"type": "单选"
},
{
"id": 56,
"question": "已知地区电网阻抗有名值归算到0.4kV侧为 Zs=0.8mΩ,求电抗有名值为()。",
"A": "0.796mΩ",
"B": "0.976mΩ",
"C": "0.679mΩ",
"D": "0.825mΩ",
"type": "单选"
},
{
"id": 57,
"question": "一台 10/0.4kV配电变压器,绕组联结为 Dynl1,二次侧两相短路时的超瞬态短路电流$I^{\"}_{22k2}$=27.7kA,则流过一次侧最大一相的电流$I^{\"}_{2k2}$为()。",
"A": "1.22kA",
"B": "0.85kA",
"C": "0. 74kA",
"D": "1.84kA",
"type": "单选"
},
{
"id": 58,
"question": "一台10/0.4kV配电变压器,绕组联结为Yyn0,二次侧两相短路时的超瞬态短路电流 $I^{\"}_{22k2}$,则流过一次侧的电流 $I^{\"}_{2k2}$为()。",
"A": "0. 384kA",
"B": "0.333kA",
"C": "0.665kA",
"D": "0.549kA",
"type": "单选"
},
{
"id": 59,
"question": "对 35kV 及以下高压负荷开关的切断,不安全的是()。",
"A": "15A电缆电容电流",
"B": "5A架空线充电电流",
"C": "1000kVA变压器空载电流",
"D": "基于额定电流的闭环电流",
"type": "单选"
},
{
"id": 60,
"question": "三绕组“升压型”变压器的绕组排列顺序自铁芯向外依次为()。",
"A": "低一高—中",
"B": "高—中—低",
"C": "高—低—中",
"D": "中—低—高",
"type": "单选"
},
{
"id": 61,
"question": "选择悬式绝缘子时不需考虑()。",
"A": "标称电压",
"B": "机械荷载",
"C": "动稳定",
"D": "绝缘水平",
"type": "单选"
},
{
"id": 62,
"question": "隔离开关的破冰厚度一般为()。",
"A": "5mm",
"B": "8mm",
"C": "10mm",
"D": "15mm",
"type": "单选"
},
{
"id": 63,
"question": "单柱垂直开启式隔离开关在分闸状态下,动静触头间的最小电气距离不应小于配电装置的最小安全净距()值。",
"A": "A",
"B": "B",
"C": "C",
"D": "D",
"type": "单选"
},
{
"id": 64,
"question": "高压电压互感器校验的项目包括()。",
"A": "额定电压",
"B": "额定电流",
"C": "额定开断电流",
"D": "短路电流动稳定、热稳定",
"type": "单选"
},
{
"id": 65,
"question": "用熔断器保护的(),可不验算动、热稳定。",
"A": "电缆",
"B": "限流电抗器",
"C": "电压互感器",
"D": "母线",
"type": "单选"
},
{
"id": 66,
"question": "普通高压电器型号后带“TA”字样,代表高压电器可以应用在长期处于低湿度年最高温度超过()的干热地区。",
"A": "35℃",
"B": "40℃",
"C": "45℃",
"D": "50℃",
"type": "单选"
},
{
"id": 67,
"question": "在轻盐碱和炉烟污秽地区,离海岸盐场3~10km地区,则该地区污秽等级为()级。",
"A": "0",
"B": "I",
"C": "Ⅱ",
"D": "Ⅲ",
"type": "单选"
},
{
"id": 68,
"question": "电容器组的接线方式,下面叙述欠妥的是()。",
"A": "高压电容器组接线方式宜采用单星形接线直接接地或双星形接线通过电压互感器接地",
"B": "在中性点非直接接地的电网中,星形接线电容器组的中性点不应接地",
"C": "高压电容器组的每相或每个桥臂,由多台电容器串并联组合时,有先并联后串联和先串联后并联两种接线方式,目前多采用先串联后并联的接线方式",
"D": "低压电容器或电容器组,可采用三角形接线或中性点不接地的星形接线方式",
"type": "单选"
},
{
"id": 69,
"question": "关于电流互感器的准确度,下列用法不合适的是()。",
"A": "用于电度计量的电流互感器,准确度不应低于0.5级",
"B": "用于500kV电度计量的电流互感器,准确度宜为0.2级",
"C": "用于电流电压测量的准确度,不应低于3级",
"D": "TP级电流互感器用于继电保护",
"type": "单选"
},
{
"id": 70,
"question": "在荷载长期作用及短时作用情况下,选择支柱绝缘子的力学安全系数应分别取()。",
"A": "2.0, 1.67",
"B": "2.5, 1.67",
"C": "4, 2.5",
"D": "5.3, 3.3",
"type": "单选"
},
{
"id": 71,
"question": "选择户外高压断路器时必须校验的环境条件是()。",
"A": "环境温度、相对湿度、污秽、地震烈度",
"B": "环境温度、相对湿度、日温差、地震烈度",
"C": "环境温度、最大风速、污秽、地震烈度",
"D": "日温差、相对湿度、最大风速、污秽",
"type": "单选"
},
{
"id": 72,
"question": "当串联电抗器的电抗率为5%时,10kV并联电容器组的额定相电压应选择()。",
"A": "10/√3kV",
"B": "10.5/√3kV",
"C": "11//3kV",
"D": "12/√3kV",
"type": "单选"
},
{
"id": 73,
"question": "在非导电灰尘的一般多尘场所的低压电器的防护等级应为()。",
"A": "IP44",
"B": "IP4X",
"C": "IP5X",
"D": "IP67",
"type": "单选"
},
{
"id": 74,
"question": "安装在室内中等腐蚀场所的按钮的防腐类型应为()。",
"A": "IP5X",
"B": "IP65",
"C": "F1 级防腐型",
"D": "WF1 级防腐型",
"type": "单选"
},
{
"id": 75,
"question": "TT系统的配电线路采用漏电电流保护器作接地故障保护时,接地故障电流($I_d$)应大于漏电保护器的额定动作电流($I_{\\Delta n}$)的()倍。",
"A": "1",
"B": "1.3",
"C": "1.5",
"D": "2",
"type": "单选"
},
{
"id": 76,
"question": "IT系统的外露可导电部分为共同接地时,发生第二次接地故障时,切断故障回路应符合()系统的接地故障保护要求。",
"A": "TN",
"B": "TT",
"C": "IT",
"D": "TN和 TT",
"type": "单选"
},
{
"id": 77,
"question": "用断路器保护供荧光灯的照明配电线路,其长延时过电流脱扣器整定电流不应小于线路计算电流的()倍。",
"A": "1",
"B": "1.2",
"C": "1.3",
"D": "1.6",
"type": "单选"
},
{
"id": 78,
"question": "按短路热稳定要求,$S \\ge \\frac{I}{K}\\sqrt{t}$式中,t值适用的范围为()K。",
"A": "t≤5s",
"B": "t≥0. 1s",
"C": "0. 4s≤t≤5s",
"D": "0.1s≤t≤5s",
"type": "单选"
},
{
"id": 79,
"question": "选择屋外裸导体使用的最高环境温度应符合()。",
"A": "极端最高温度",
"B": "年最高温度平均值",
"C": "最热月平均温度",
"D": "最热月平均最高温度 (最热月的日最高温度平均值)",
"type": "单选"
},
{
"id": 80,
"question": "低压配电系统导体截面选择,下列说法中不正确的是()。",
"A": "线路电压损失应满足用电设备正常工作和启动时端电压的要求",
"B": "按敷设方式及环境条件确定的导体载流量不应小于计算电流",
"C": "导体最小截面应满足机械强度的要求",
"D": "软导线满足动稳定和热稳定的要求",
"type": "单选"
},
{
"id": 81,
"question": "以气体放电灯为主要负荷的回路中,其中性线截面应()。",
"A": "按线路中最大不平衡负荷电流计算,且应计入谐波电流的影响",
"B": "不小于相线截面",
"C": "按最大相电流计算,且计入谐波电流的影响",
"D": "为相线截面的 1/2",
"type": "单选"
},
{
"id": 82,
"question": "选择硬导体形状时不需考虑的因素是()。",
"A": "集肤效应",
"B": "热屏蔽效应",
"C": "电晕",
"D": "腐蚀性气.体",
"type": "单选"
},
{
"id": 83,
"question": "直埋电缆的接头与相邻电缆的净距不应小于()。",
"A": "0.1m",
"B": "0.25m",
"C": "0.5m",
"D": "1.0m",
"type": "单选"
},
{
"id": 84,
"question": "同一层支架上电缆排列配置方式不符合规定的是()。",
"A": "控制和信号电缆可紧靠或多层迭置",
"B": "同一回路多根电力电缆可以迭置",
"C": "交流系统用单芯电力电缆的同一回路可采用品字形配置",
"D": "控制电缆与电力电缆尽可能不同层布置",
"type": "单选"
},
{
"id": 85,
"question": "自容式铝包充油电缆,允许弯曲半径可按电缆外径的()倍计算。",
"A": "6",
"B": "20",
"C": "12",
"D": "15",
"type": "单选"
},
{
"id": 86,
"question": "高温场所不宜用()。",
"A": "耐热聚氯乙烯电缆",
"B": "普通交联聚乙烯电缆",
"C": "聚氯乙烯绝缘电缆",
"D": "乙丙橡皮绝缘电缆",
"type": "单选"
},
{
"id": 87,
"question": "在空气中,电线穿钢管4根并列单层敷设在无孔托盘上时载流量的校正系数为()。",
"A": "0.7",
"B": "0.8",
"C": "0.75",
"D": "0.95",
"type": "单选"
},
{
"id": 88,
"question": "在竖井中,宜每隔约()设置阻火隔层。",
"A": "9m",
"B": "7m",
"C": "6m",
"D": "3m",
"type": "单选"
},
{
"id": 89,
"question": "3~10kV高压架空线路铜绞线不应小于()。",
"A": "10mm²",
"B": "16mm²",
"C": "25mm²",
"D": "35mm²",
"type": "单选"
},
{
"id": 90,
"question": "耐火电缆用于明敷有多根电缆配置中,或位于油罐区、熔化金属溅落等可能波及场所时,其耐火性应符合GB/T12666一1990《电线电缆燃烧试验方法》的规定,并满足该标准第6 部分()类的要求。",
"A": "A",
"B": "B",
"C": "C",
"D": "D",
"type": "单选"
},
{
"id": 91,
"question": "沿不同冷却的路径敷设绝缘导线和电缆时,当冷却条件最坏段的长度超过()应按该段条件选择绝缘导线和电缆的截面,或只对该段采用大截面的绝缘导线和电缆。",
"A": "3m",
"B": "5m",
"C": "10m",
"D": "15m",
"type": "单选"
},
{
"id": 92,
"question": "按回路正常工作电流选择导体截面时,导体的长期允许载流量应按()进行修正。",
"A": "所在地区海拔及环境温度",
"B": "所在地区海拔及环境湿度",
"C": "所在地区污秽及环境湿度",
"D": "所在地区污秽及环境温度",
"type": "单选"
},
{
"id": 93,
"question": "控制电缆应采用()。",
"A": "铝芯",
"B": "铜芯",
"C": "钢芯",
"D": "光纤",
"type": "单选"
},
{
"id": 94,
"question": "在户内电缆沟、隧道敷设并无机械通风的情况下,确定电缆持续允许载流量的环境温度为()。",
"A": "年平均最高温度",
"B": "最热月的日最高温度平均值加5℃",
"C": "年平均最低温度",
"D": "最热月的日最高温度平均值",
"type": "单选"
},
{
"id": 95,
"question": "相线截面为16mm²及以下时,相同材质的 PE线截面不应小于相线的()。",
"A": "0.5",
"B": "1",
"C": "按谐波电流确定",
"D": "按接地故障电流确定",
"type": "单选"
},
{
"id": 96,
"question": "对遥控及无人值班变配电所的控制回路宜采用()。",
"A": "控制开关自动复位的接线",
"B": "控制开关具有固定位置的接线",
"C": "分合按钮的接线",
"D": "带有灯光的分合按钮的接线",
"type": "单选"
},
{
"id": 97,
"question": "1.0级及 2.0 级的电能表处电压降不得大于电压互感器额定二次电压的()。",
"A": "0.0025",
"B": "0.005",
"C": "0.01",
"D": "0.015",
"type": "单选"
},
{
"id": 98,
"question": "主变压器的接线为Ydl1,当装设纵差保护时,电流互感器的接线应为()。",
"A": "Yy",
"B": "Dd",
"C": "Dy",
"D": "Yd",
"type": "单选"
},
{
"id": 99,
"question": "电容器内部故障及其引出线的短路,宜对每台电容器分别设专用熔断器,熔丝的额定电流可为电容器额定电流的()倍。",
"A": "1.3~1.5",
"B": "1.3~1.8",
"C": "1. 43~1.55",
"D": "17~2.0",
"type": "单选"
},
{
"id": 100,
"question": "电力系统中因事故发生功率缺额时,应由()断开一部分次要负荷。",
"A": "值班人员手动",
"B": "自动低频减载装置",
"C": "自动低电压减载装置",
"D": "调度员命令",
"type": "单选"
},
{
"id": 101,
"question": "控制屏上采用灯光监视时,红、绿灯代表断路器的合闸与分闸状态,它们分别布置在控制开关的()。",
"A": "右下侧和左下侧",
"B": "左下侧和右下侧",
"C": "左上侧和右上侧",
"D": "右上侧和左上侧",
"type": "单选"
},
{
"id": 102,
"question": "直流仪表配用外附分流器的精确度等级,不应低于()级。",
"A": "0. 5",
"B": "1",
"C": "1.5",
"D": "2",
"type": "单选"
},
{
"id": 103,
"question": "继电保护、自动装置、控制、信号的二次回路线路中的操作回路,在最大负荷下,操作母线至设备的电压降,不应超过额定电压的()。",
"A": "0.05",
"B": "0.1",
"C": "0.15",
"D": "0.2",
"type": "单选"
},
{
"id": 104,
"question": "控制电缆宜采用多芯电缆,应尽可能减少电缆根数,当芯线截面为 2.5mm²时,电缆芯数不宜超过()。",
"A": "10",
"B": "19",
"C": "24",
"D": "37",
"type": "单选"
},
{
"id": 105,
"question": "对()及以上容量的低压电动机回路宜测量交流电流。",
"A": "30kW",
"B": "47kW",
"C": "55kW",
"D": "75kW",
"type": "单选"
},
{
"id": 106,
"question": "断路器的防跳回路,以下说法正确的是()。",
"A": "由断路器辅助触点及中间继电器组成防跳回路接线",
"B": "由断路器辅助触点及串接电阻组成防跳回路接线",
"C": "采用电流启动电压自保持的防跳回路接线",
"D": "由断路器辅助触点和由电流启动并保持的防跳回路接线",
"type": "单选"
},
{
"id": 107,
"question": "110kV中性点直接接地电力网的线路保护中,相间保护电流回路的电流互感器采用()方式。",
"A": "采用两相式电流互感器",
"B": "采用三相三角形接线",
"C": "采用三相星形接线",
"D": "采用三相三角形或三相星形接线",
"type": "单选"
},
{
"id": 108,
"question": "中型配电所当装有电磁操动机构时,合闸宜采用()。",
"A": "110kV蓄电池组",
"B": "硅整流",
"C": "220V蓄电池组",
"D": "小容量镉镍电池装置",
"type": "单选"
},
{
"id": 109,
"question": "控制负荷系统的直流母线电压允许在直流系统额定电压的变化范围是()。",
"A": "85%~110%",
"B": "85%~112.5%",
"C": "87.5%~110%",
"D": "87.5%~112.5%",
"type": "单选"
},
{
"id": 110,
"question": "变电所的直流冲击负荷主要是()。",
"A": "断路器合闸时的短时冲击电流",
"B": "电动机起动直流",
"C": "消防设备电流",
"D": "电容器的充电电流",
"type": "单选"
},