Update Register 101, 102, 200 and added COP #54

Merged
merged 6 commits into from
Oct 21, 2024
Merged

Conversation

rysiulg
Copy link
Contributor

@rysiulg rysiulg commented Oct 20, 2024

Added COP -efficiency of heat pump -tells how much energy is produced from 1kWh of energy consumed -eg 3.69 means 3.69 more kWh energy in heat was produced consumed 1kWh of power energy -bigger is better
moved register 101 to text sensor with status from hp -status 5 was missing in service manual but is assumed as dhw heat
register 200 is moved to text sensor and decoded with apliance type etc with easly add new values if needed -for only alreadey filled i have data

I decided to send these 4 together -there isn't too much change.
about 271 we can discus tomorrow ;) -i propose to add check to not out of range array ;)

Added COP -efficiency of heat pump -tells how much energy is produced from 1kWh of energy consumed -eg 3.69 means 3.69 more kWh energy in heat was produced consumed 1kWh of power energy -bigger is better
moved register 101 to text sensor with status from hp -status 5 was missing in service manual but is assumed as dhw heat
register 200 is moved to text sensor and decoded with apliance type etc with easly add new values if needed -for only alreadey filled i have data
Added COP -efficiency of heat pump -tells how much energy is produced from 1kWh of energy consumed -eg 3.69 means 3.69 more kWh energy in heat was produced consumed 1kWh of power energy -bigger is better
moved register 101 to text sensor with status from hp -status 5 was missing in service manual but is assumed as dhw heat
register 200 is moved to text sensor and decoded with apliance type etc with easly add new values if needed -for only alreadey filled i have data
heatpump.yaml Outdated
output += to_string(rawdata);
if (rawdata == 0) output = "OFF";
else if (rawdata == 2) output = "Cooling";
else if (rawdata == 3) output = "CO Heating";
Copy link
Owner

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

"CO Heating" -> "Heating"

@rysiulg
Copy link
Contributor Author

rysiulg commented Oct 20, 2024 via email

@Mosibi
Copy link
Owner

Mosibi commented Oct 20, 2024

Register 101 is the sensor for register 1, where the operational mode is selected. I am very surprised that York shows that is doing a DHW thing, but if it does, then let’s enjoy it and keep it in !

@rysiulg
Copy link
Contributor Author

rysiulg commented Oct 21, 2024

Register 101 is the sensor for register 1, where the operational mode is selected. I am very surprised that York shows that is doing a DHW thing, but if it does, then let’s enjoy it and keep it in !

OK.
Maybe firmware version? -I have my York installed by me in November 2022 -so maybe this is firmware issue with older HeatPump wthich don't have implemented this indication?
In service manual value of 5 doesn't exist, so in this config this don't make any mess -i think it can be only update ;)

@Mosibi Mosibi merged commit aac530c into Mosibi:master Oct 21, 2024
@Mosibi
Copy link
Owner

Mosibi commented Oct 21, 2024

Thanks again!