Notifications
You must be signed in to change notification settings - Fork 25
/
Copy pathargononed.py
executable file
·618 lines (544 loc) · 23 KB
/
argononed.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
#!/usr/bin/python3
#
# This script set fan speed and monitor power button events.
#
# Fan Speed is set by sending 0 to 100 to the MCU (Micro Controller Unit)
# The values will be interpreted as the percentage of fan speed, 100% being maximum
#
# Power button events are sent as a pulse signal to BCM Pin 4 (BOARD P7)
# A pulse width of 20-30ms indicates reboot request (double-tap)
# A pulse width of 40-50ms indicates shutdown request (hold and release after 3 secs)
#
# Additional comments are found in each function below
#
# Standard Deployment/Triggers:
# * Raspbian, OSMC: Runs as service via /lib/systemd/system/argononed.service
# * lakka, libreelec: Runs as service via /storage/.config/system.d/argononed.service
# * recalbox: Runs as service via /etc/init.d/
#
# For Libreelec/Lakka, note that we need to add system paths
# import sys
# sys.path.append('/storage/.kodi/addons/virtual.rpi-tools/lib')
import RPi.GPIO as GPIO
from pathlib import Path
import sys
import os
import time
from threading import Thread
from queue import Queue
sys.path.append("/etc/argon/")
from argonsysinfo import *
from argonlogging import *
from argonconfig import *
from version import *
# Initialize I2C Bus
import smbus
rev = GPIO.RPI_REVISION
if rev == 2 or rev == 3:
bus=smbus.SMBus(1)
else:
bus=smbus.SMBus(0)
CONFIG_FILE='/etc/argoneon.conf'
OLED_ENABLED=False
#
# Enable logging
#
if os.path.exists("/etc/argon/argoneonoled.py"):
import datetime
from argoneonoled import *
OLED_ENABLED=True
#
# Enable debug logging if requested
#
enableLogging( loadDebugMode() )
ADDR_FAN=0x1a
PIN_SHUTDOWN=4
GPIO.setwarnings(False)
GPIO.setmode(GPIO.BCM)
GPIO.setup(PIN_SHUTDOWN, GPIO.IN, pull_up_down=GPIO.PUD_DOWN)
# This function is the thread that monitors activity in our shutdown pin
# The pulse width is measured, and the corresponding shell command will be issued
def shutdown_check(writeq):
while True:
pulsetime = 1
GPIO.wait_for_edge(PIN_SHUTDOWN, GPIO.RISING)
time.sleep(0.01)
while GPIO.input(PIN_SHUTDOWN) == GPIO.HIGH:
time.sleep(0.01)
pulsetime += 1
if pulsetime >=2 and pulsetime <=3:
# Testing
#writeq.put("OLEDSWITCH")
writeq.put("OLEDSTOP")
os.system("reboot")
elif pulsetime >=4 and pulsetime <=5:
writeq.put("OLEDSTOP")
os.system("shutdown now -h")
elif pulsetime >=6 and pulsetime <=7:
writeq.put("OLEDSWITCH")
#
#
#
def get_fanspeed(tempval, configlist):
"""
This function converts the corresponding fanspeed for the given temperature the
configutation data is a list of strings in the form "<temperature>:<speed>"
"""
retval = 0
if len(configlist) > 0:
for k in configlist.keys():
if tempval >= float(k):
retval=int(configlist[k])
logDebug( "Temperature (" + str(tempval) + ") >= " + str(k) + " suggesting fanspeed of " + str(retval) )
logDebug( "Returning fanspeed of " + str(retval))
return retval
# This function is the thread that monitors temperature and sets the fan speed
# The value is fed to get_fanspeed to get the new fan speed
# To prevent unnecessary fluctuations, lowering fan speed is delayed by 30 seconds
#
# Location of config file varies based on OS
#
def setFanOff ():
setFanSpeed (overrideSpeed = 0)
def setFanFlatOut ():
setFanSpeed (overrideSpeed = 100)
def setFanSpeed (overrideSpeed : int = None, instantaneous : bool = True):
"""
Set the fanspeed. Support override (overrideSpeed) with a specific value, and
an instantaneous change. Some hardware does not like the sudden change, it wants the
speed set to 100% THEN changed to the new value. Not really sure why this is.
"""
prevspeed = argonsysinfo_getCurrentFanSpeed()
if not prevspeed:
prevspeed = 0
argonsysinfo_recordCurrentFanSpeed( prevspeed )
if overrideSpeed is not None:
newspeed = overrideSpeed
else:
newspeed = max([get_fanspeed(argonsysinfo_getcputemp(), loadCPUFanConfig())
,get_fanspeed(argonsysinfo_getmaxhddtemp(), loadHDDFanConfig())
]
)
if newspeed < prevspeed and not instantaneous:
# Pause 30s before speed reduction to prevent fluctuations
time.sleep(30)
# Make sure the value is in 0-100 range
newspeed = max([min([100,newspeed]),0])
if overrideSpeed is not None or (prevspeed != newspeed):
try:
if newspeed > 0:
# Spin up to prevent issues on older units
bus.write_byte(ADDR_FAN,100)
time.sleep(1)
bus.write_byte(ADDR_FAN,int(newspeed))
logging.debug( "writing to fan port, speed " + str(newspeed))
argonsysinfo_recordCurrentFanSpeed( newspeed )
except IOError:
logError( "Error trying o update fan speed.")
return prevspeed
return newspeed
def temp_check():
"""
Main thread for processing the temperature check functonality. We just try and set the fan speed once
a minute. However we do want to start with the fan *OFF*.
"""
setFanOff()
while True:
setFanSpeed (instantaneous = False)
time.sleep(60)
#
# This function is the thread that updates OLED
#
def display_loop(readq):
weekdaynamelist = ["Mon", "Tue", "Wed", "Thu", "Fri", "Sat", "Sun"]
monthlist = ["JAN", "FEB", "MAR", "APR", "MAY", "JUN", "JUL", "AUG", "SEP", "OCT", "NOV", "DEC"]
oledscreenwidth = oled_getmaxX()
fontwdSml = 6 # Maps to 6x8
fontwdReg = 8 # Maps to 8x16
stdleftoffset = 54
temperature="C"
temperature = loadTempConfig()
print( "Temperature config is " + temperature )
screensavermode = False
screensaversec = 120
screensaverctr = 0
screenenabled = ["clock", "ip"]
prevscreen = ""
curscreen = ""
screenid = 0
screenjogtime = 0
screenjogflag = 0 # start with screenid 0
cpuusagelist = []
curlist = []
tmpconfig=loadOLEDConfig()
if "screensaver" in tmpconfig:
screensaversec = int(tmpconfig["screensaver"])
if "screenduration" in tmpconfig:
screenjogtime = int(tmpconfig["screenduration"])
if "screenlist" in tmpconfig:
screenenabled = tmpconfig["screenlist"].replace("\"","").split(" ")
if "enabled" in tmpconfig:
if tmpconfig["enabled"] == "N":
screenenabled = []
#
# Setup some variables to help calculate bandwidth
#
timespan = 1
prevData = argonsysinfo_diskusage()
prevTime = time.clock_gettime_ns(time.CLOCK_MONOTONIC)
while len(screenenabled) > 0:
if len(curlist) == 0 and screenjogflag == 1:
# Reset Screen Saver
screensavermode = False
screensaverctr = 0
# Update screen info
screenid = screenid + screenjogflag
if screenid >= len(screenenabled):
screenid = 0
prevscreen = curscreen
curscreen = screenenabled[screenid]
if screenjogtime == 0:
# Resets jogflag (if switched manually)
screenjogflag = 0
else:
screenjogflag = 1
needsUpdate = False
if curscreen == "cpu":
# CPU Usage
if len(curlist) == 0:
try:
if len(cpuusagelist) == 0:
cpuusagelist = argonsysinfo_listcpuusage()
curlist = cpuusagelist
except:
logError( "Error processing information for CPU display")
curlist = []
if len(curlist) > 0:
oled_loadbg("bgcpu")
# Display List
yoffset = 0
tmpmax = 4
while tmpmax > 0 and len(curlist) > 0:
curline = ""
tmpitem = curlist.pop(0)
curline = tmpitem["title"]+": "+str(tmpitem["value"])+"%"
oled_writetext(curline, stdleftoffset, yoffset, fontwdSml)
oled_drawfilledrectangle(stdleftoffset, yoffset+12, int((oledscreenwidth-stdleftoffset-4)*tmpitem["value"]/100), 2)
tmpmax = tmpmax - 1
yoffset = yoffset + 16
needsUpdate = True
else:
# Next page due to error/no data
screenjogflag = 1
elif curscreen == "storage":
# Storage Info
if len(curlist) == 0:
try:
tmpobj = argonsysinfo_listhddusage()
for curdev in tmpobj:
curlist.append({"title": curdev, "value": argonsysinfo_kbstr(tmpobj[curdev]['total']), "usage": int(tmpobj[curdev]['percent']) })
#curlist = argonsysinfo_liststoragetotal()
except:
logError( "Error processing information for STORAGE display")
curlist = []
if len(curlist) > 0:
oled_loadbg("bgstorage")
yoffset = 16
tmpmax = 3
while tmpmax > 0 and len(curlist) > 0:
tmpitem = curlist.pop(0)
# Right column first, safer to overwrite white space
oled_writetextaligned(tmpitem["value"], 77, yoffset, oledscreenwidth-77, 2, fontwdSml)
oled_writetextaligned(str(tmpitem["usage"])+"%", 50, yoffset, 74-50, 2, fontwdSml)
tmpname = tmpitem["title"]
if len(tmpname) > 8:
tmpname = tmpname[0:8]
oled_writetext(tmpname, 0, yoffset, fontwdSml)
tmpmax = tmpmax - 1
yoffset = yoffset + 16
needsUpdate = True
else:
# Next page due to error/no data
screenjogflag = 1
elif curscreen == "bandwidth":
# Bandwidth info
if len(curlist) == 0:
try:
diskdata = argonsysinfo_diskusage()
for istop in diskdata:
for istart in prevData:
if istop['disk'] == istart['disk']:
istart['readsector'] = istop['readsector'] - istart['readsector']
istart['writesector'] = istop['writesector'] - istart['writesector']
curlist = prevData
prevData = diskdata
stoptime = time.clock_gettime_ns(time.CLOCK_MONOTONIC)
timespan = (stoptime - prevTime)/1000000000
prevTime = stoptime
except:
logError( "Error processing data for BANDWIDTH display")
curlist = []
if len(curlist) > 0:
oled_clearbuffer()
oled_writetextaligned( "BANDWIDTH", 0, 0, oledscreenwidth, 1, fontwdSml)
oled_writetextaligned( "Write", 77, 16, oledscreenwidth-77, 2, fontwdSml)
oled_writetextaligned( "Read", 50, 16, 74-50, 2, fontwdSml)
oled_writetext( "Device", 0, 16, fontwdSml )
itemcount = 2
yoffset = 32
while itemcount > 0 and len(curlist) >0:
item = curlist.pop(0)
bandwidth = int((item['writesector']/2)/timespan)
oled_writetextaligned( argonsysinfo_kbstr(bandwidth), 77, yoffset, oledscreenwidth-77, 2, fontwdSml )
bandwidth = int((item['readsector']/2)/timespan)
oled_writetextaligned( argonsysinfo_kbstr(bandwidth), 50, yoffset, 74-50, 2, fontwdSml )
oled_writetext( item['disk'], 0, yoffset, fontwdSml )
itemcount = itemcount - 1
yoffset = yoffset + 16
needsUpdate = True
else:
# Next Page due to error/no data
screenjogFlag = 1
elif curscreen == "raid":
# Raid Info
if len(curlist) == 0:
try:
tmpobj = argonsysinfo_listraid()
curlist = tmpobj['raidlist']
except:
logError( "Error processing display of RAID information.")
curlist = []
if len(curlist) > 0:
oled_loadbg("bgraid")
tmpitem = curlist.pop(0)
oled_writetextaligned(tmpitem["title"], 0, 0, stdleftoffset, 1, fontwdSml)
oled_writetextaligned(tmpitem["value"], 0, 8, stdleftoffset, 1, fontwdSml)
oled_writetextaligned(argonsysinfo_kbstr(tmpitem["info"]["size"]), 0, 56, stdleftoffset, 1, fontwdSml)
rebuild = tmpitem['info']['resync']
statusList = tmpitem['info']['state'].split(", ")
if len(statusList) == 1:
status = statusList[0]
if len(statusList) == 2:
status = statusList[1]
if len(statusList) >=3:
status = statusList[2]
status = status.capitalize()
oled_writetext( status, stdleftoffset, 8, fontwdSml )
if len(rebuild) > 0:
percent = rebuild.split( " " )
if status.lower() == "checking":
label = "Progess: "
else:
label = "Rebuild: "
oled_writetext(label + percent[0], stdleftoffset, 16, fontwdSml)
oled_writetext("Active:"+str(int(tmpitem["info"]["active"]))+"/"+str(int(tmpitem["info"]["devices"])), stdleftoffset, 32, fontwdSml)
oled_writetext("Working:"+str(int(tmpitem["info"]["working"]))+"/"+str(int(tmpitem["info"]["devices"])), stdleftoffset, 40, fontwdSml)
oled_writetext("Failed:"+str(int(tmpitem["info"]["failed"]))+"/"+str(int(tmpitem["info"]["devices"])), stdleftoffset, 48, fontwdSml)
needsUpdate = True
else:
# Next page due to error/no data
screenjogflag = 1
elif curscreen == "ram":
# RAM
try:
oled_loadbg("bgram")
tmpraminfo = argonsysinfo_getram()
oled_writetextaligned(tmpraminfo["percent"]+"%", stdleftoffset, 8, oledscreenwidth-stdleftoffset, 1, fontwdReg)
oled_writetextaligned("of", stdleftoffset, 24, oledscreenwidth-stdleftoffset, 1, fontwdReg)
oled_writetextaligned(tmpraminfo["gb"]+"GB", stdleftoffset, 40, oledscreenwidth-stdleftoffset, 1, fontwdReg)
needsUpdate = True
except:
logError( "Error processing information for RAM display")
needsUpdate = False
# Next page due to error/no data
screenjogflag = 1
elif curscreen == "temp":
# Temp
try:
oled_loadbg("bgtemp")
hddtempctr = 0
maxcval = 0
mincval = 200
# Get min/max of hdd temp
hddtempobj = argonsysinfo_gethddtemp()
for curdev in hddtempobj:
if hddtempobj[curdev] < mincval:
mincval = hddtempobj[curdev]
if hddtempobj[curdev] > maxcval:
maxcval = hddtempobj[curdev]
hddtempctr = hddtempctr + 1
cpucval = argonsysinfo_getcputemp()
if hddtempctr > 0:
alltempobj = {"cpu": cpucval,"hdd min": mincval, "hdd max": maxcval}
# Update max C val to CPU Temp if necessary
if maxcval < cpucval:
maxcval = cpucval
displayrowht = 8
displayrow = 8
for curdev in alltempobj:
if temperature == "C":
# Celsius
tmpstr = str(alltempobj[curdev])
if len(tmpstr) > 4:
tmpstr = tmpstr[0:4]
else:
# Fahrenheit
tmpstr = str(32+9*(alltempobj[curdev])/5)
if len(tmpstr) > 5:
tmpstr = tmpstr[0:5]
if len(curdev) <= 3:
oled_writetext(curdev.upper()+": "+ tmpstr+ chr(167) +temperature, stdleftoffset, displayrow, fontwdSml)
else:
oled_writetext(curdev.upper()+":", stdleftoffset, displayrow, fontwdSml)
oled_writetext(" "+ tmpstr+ chr(167) +temperature, stdleftoffset, displayrow+displayrowht, fontwdSml)
displayrow = displayrow + displayrowht*2
else:
maxcval = cpucval
if temperature == "C":
# Celsius
tmpstr = str(cpucval)
if len(tmpstr) > 4:
tmpstr = tmpstr[0:4]
else:
# Fahrenheit
tmpstr = str(32+9*(cpucval)/5)
if len(tmpstr) > 5:
tmpstr = tmpstr[0:5]
oled_writetextaligned(tmpstr+ chr(167) +temperature, stdleftoffset, 24, oledscreenwidth-stdleftoffset, 1, fontwdReg)
# Temperature Bar: 40C is min, 80C is max
maxht = 21
barht = int(maxht*(maxcval-40)/40)
if barht > maxht:
barht = maxht
elif barht < 1:
barht = 1
oled_drawfilledrectangle(24, 20+(maxht-barht), 3, barht, 2)
needsUpdate = True
except:
logError( "Error processing temerature information for TEMP display" )
needsUpdate = False
# Next page due to error/no data
screenjogflag = 1
elif curscreen == "ip":
# IP Address
try:
if len(curlist) == 0:
curlist = argonsysinfo_getipList()
except:
logError( "Error processing information for IP display")
curlist = []
if len(curlist) > 0:
item = curlist.pop(0)
oled_loadbg("bgip")
oled_writetextaligned(item[0], 0, 0, oledscreenwidth, 1, fontwdReg)
oled_writetextaligned(item[1], 0,16, oledscreenwidth, 1, fontwdReg)
needsUpdate = True
else:
needsUpdate = False
# Next page due to error/no data
screenjogflag = 1
else:
try:
oled_loadbg("bgtime")
# Date and Time HH:MM
curtime = datetime.datetime.now()
# Month/Day
outstr = str(curtime.day).strip()
if len(outstr) < 2:
outstr = " "+outstr
outstr = monthlist[curtime.month-1]+outstr
oled_writetextaligned(outstr, stdleftoffset, 8, oledscreenwidth-stdleftoffset, 1, fontwdReg)
# Day of Week
oled_writetextaligned(weekdaynamelist[curtime.weekday()], stdleftoffset, 24, oledscreenwidth-stdleftoffset, 1, fontwdReg)
# Time
outstr = str(curtime.minute).strip()
if len(outstr) < 2:
outstr = "0"+outstr
outstr = str(curtime.hour)+":"+outstr
if len(outstr) < 5:
outstr = "0"+outstr
oled_writetextaligned(outstr, stdleftoffset, 40, oledscreenwidth-stdleftoffset, 1, fontwdReg)
needsUpdate = True
except:
logError( "Error processing information of TIME display" )
needsUpdate = False
# Next page due to error/no data
screenjogflag = 1
if needsUpdate == True:
if screensavermode == False:
# Update screen if not screen saver mode
oled_power(True)
oled_flushimage(prevscreen != curscreen)
oled_reset()
timeoutcounter = 0
while timeoutcounter<screenjogtime or screenjogtime == 0:
qdata = ""
if readq.empty() == False:
qdata = readq.get()
if qdata == "OLEDSWITCH":
# Trigger screen switch
screenjogflag = 1
# Reset Screen Saver
screensavermode = False
screensaverctr = 0
break
elif qdata == "OLEDSTOP":
# End OLED Thread
display_defaultimg()
return
else:
screensaverctr = screensaverctr + 1
if screensaversec <= screensaverctr and screensavermode == False:
screensavermode = True
oled_fill(0)
oled_reset()
oled_power(False)
if timeoutcounter == 0:
# Use 1 sec sleep get CPU usage
cpuusagelist = argonsysinfo_listcpuusage(1)
else:
time.sleep(1)
timeoutcounter = timeoutcounter + 1
if timeoutcounter >= 60 and screensavermode == False:
# Refresh data every minute, unless screensaver got triggered
screenjogflag = 0
break
display_defaultimg()
def display_defaultimg():
# Load default image
#oled_power(True)
#oled_loadbg("bgdefault")
#oled_flushimage()
oled_fill(0)
oled_reset()
if len(sys.argv) > 1:
cmd = sys.argv[1].upper()
if cmd == "SHUTDOWN":
# Signal poweroff
logInfo( "SHUTDOWN requested via shutdown of command of argononed service")
setFanOff()
bus.write_byte(ADDR_FAN,0xFF)
elif cmd == "FANOFF":
# Turn off fan
setFanOff()
logInfo( "FANOFF requested via fanoff command of the argononed service")
if OLED_ENABLED == True:
display_defaultimg()
elif cmd == "SERVICE":
# Starts the power button and temperature monitor threads
try:
logInfo( "argononed service version " + ARGON_VERSION + " starting.")
ipcq = Queue()
t1 = Thread(target = shutdown_check, args =(ipcq, ))
t2 = Thread(target = temp_check)
if OLED_ENABLED == True:
t3 = Thread(target = display_loop, args =(ipcq, ))
t1.start()
t2.start()
if OLED_ENABLED == True:
t3.start()
ipcq.join()
except:
GPIO.cleanup()
elif cmd == "VERSION":
print( "Version: " + ARGON_VERSION )