Description of configuration in README.md appears to be outdated #94
Comments
Thank you very much for gathering all the missing informations. We will try to update the readme file soon. Until we will update the readme, please feel free to ask any questions regarding these informations. |
@sergeantd83 I'm basically struggling with the following: my home has underfloor heating on the groundfloor and radiators with Sonoff TRVZB TRVs in the bedrooms. The underfloor is controlled by a Generic Thermostat in HA that switches the underfloor pump. The TRVs are controlled by individual Versatile Thermostat instances (https://github.com/jmcollin78/versatile_thermostat).
When only the underfloor is heating and radiators are closed, the return temperature is much lower (sorry for the inconsistent coloring): I also found #88 PR which seems to add better balancing of generated power, but I'm not sure if it will help in my situation. Thanks for your help! |
It’s likely that the Versatile climate entities are causing the issue by setting a high setpoint in the TRV climate entities. I believe you have two proposed solutions:
During the initial configuration, add the Versatile climate entities in the rooms section instead of the TRV climate entities.
Let me know if you need further clarification! |
Yes, the delta will be rather big, as the temperature in the bedrooms is maybe only 15 degrees and the target is set to 20. However I don't see how this is related to the type of thermostat (Versatile or Generic) ; it's just the result of setting a target that causes a large error.
That is indeed how I configured it. The TRVs are recognized as climate entries themselves by HA, with the limitation that the TRVs will control the temperature locally. I'd like to have a temparature sensor somewhere else in the room, so I put a Versatile Thermostat 'on top of' the TRV climate entry. This in itself works correctly, as the valves open and close depending on the temperature error from the room temperature sensor.
Maybe I could build something where the increase in room setpoint is determined by the room capacity, or something. |
Then you can try the Heating mode |
The tabs when configuring SAT appear to contain different options than described in README.md.
General
SAT 4.1.2 install in HA (in Dutch, but you get the point):

Differences w.r.t. the description in the section of the README.md file for 4.1.2:
Presets
No description of both 'synchronization options'.
System configuration
Completely missing from the README.md.
Advanced
No description of 'Simulation', 'Error monitoring', 'Enforce PWM', 'Offset of climate valve', 'Sample time' (translated from Dutch, so actual terms may differ).
It seems that the readme is just outdated.